Manual Aroha SM03

Aroha Safety Pro Mini Smoke Detector

Step-by-step instructions to install and assemble the smoke detector.

Simplified visual instruction to install the smoke detector.

More on maintenance, cleaning and test and silence mode.

Installation instruction

Installation video

Trouble shooting

LED & alarm indicators

Mode

Alarm & Test

Silence/mute

Low battery

Error message

LED

Red, 1x per second

Red, 1x every 8 seconds

Red, 1x per 56 seconds

Red, 1x every 40 seconds

Alarm/Beep

1x per second

1x per 56 seconds

1x per 40 seconds

Unexpected (false) alarm

Check if there is any danger from smoke and/or fire nearby. Once danger is ruled out, press the test button to set silent mode.

To prevent future false alarms, clean and maintain the smoke detector as directed. Also consider hanging the smoke detector in another location, should it give a false alarm due to e.g. water vapors.

No alarm

Verify that the smoke detector is activated. You activate the smoke detector by turning the switch on the back to“ON“.

Low battery

The battery is low; the detector should be replaced. Contact us to exchange it if it is still under warranty.

Error message

Clean the detector by using a vacuum cleaner with a soft brush and vacuuming all sides and covers of the detector. If the problem persists, the detector is not working properly. Contact us to exchange it if it is under warranty.

Good to know

Maintenance & cleaning

Test the smoke detector once a month.
Clean the smoke detector at least once a month to remove dust, dirt or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke detector.
Do not paint the smoke detector, as paint closes the vents and interferes with the sensor’s ability to detect smoke.
Do not disassemble the smoke detector to clean the inside or replace the battery, for example, as this will damage the smoke detector.

Test mode

Test the smoke detector by pressing the test button. Then the alarm sounds three times and the red LED light flashes, followed by a short pause and another three times alarm and red LED light.

Note: Test the smoke detector once a month. Do not test the smoke detector with an open flame. This may damage the detector or ignite combustible materials and cause a structural fire. Do not stand near the detector when the alarm sounds. Close-range exposure can be harmful to your ears.

Silent mode

Silent mode should be used only when the source of the alarm is known and safe. Press the test button to set the silent mode. During this silence mode, the red LED flashes once every 8 seconds. The smoke detector automatically resets after 10 minutes.

Irreplaceable battery

The battery cannot be replaced. Both the battery and the sensor have the same lifespan. So we recommend replacing the smoke detector as soon as the battery runs out.
Do not attempt to replace the battery as this will render the smoke detector inoperable and may cause a fire due to the high capacity lithium battery.
Please contact us to exchange it if it is still under warranty.